CGA580石化高純氣體減壓閥技術(shù)規(guī)范 氣瓶減壓閥,單級(jí)式膜片減壓結(jié)構(gòu),不銹鋼膜片壓力傳輸,輸出壓力穩(wěn)定,適用于純凈氣體、標(biāo)準(zhǔn)氣體、腐蝕性氣體等。用用于石油化工、化纖、照明電器、熱處理、冶金、玻璃、食品、醫(yī)藥、電子、國(guó)防航天、航空等主導(dǎo)領(lǐng)域。CGA580高純氣體減壓閥(減壓器):單級(jí)式不銹鋼膜片減壓結(jié)構(gòu),輸出壓力穩(wěn)定,適用于高純氣體氙氣、高純氮?dú)狻⒏呒儦鍤?、純凈氣體、標(biāo)準(zhǔn)氣體、腐蝕性氣體等。 CGA580石化高純氣體減壓閥技術(shù)規(guī)范設(shè)計(jì)特點(diǎn): • 單級(jí)式減壓結(jié)構(gòu) • CGA580高純氣體減壓閥(減壓器)母體與膜片采用硬密封形式 (可抽真空) • 母體螺紋:1/4" NPT(F) • 內(nèi)部結(jié)構(gòu)易吹掃 • 內(nèi)設(shè)過濾網(wǎng) • 可采用面板式或墻式安裝 CGA580石化高純氣體減壓閥技術(shù)規(guī)范適用范圍: • 實(shí)驗(yàn)室 • 氣相色譜儀 • 氣體激光器、照明 • 氣體匯流排、太陽能光伏產(chǎn)品 • 石油化學(xué)工業(yè) • 測(cè)試設(shè)備 • 壓力表刻度單位:PSI/BAR或MPA可選 • 進(jìn)、出接頭根據(jù)客戶要求配置
CGA580石化高純氣體減壓閥技術(shù)規(guī)范材質(zhì): • 母體:316L , Brass (銅鍍鎳) • 上蓋:316L , Brass (銅鍍鎳) • 膜片:哈氏合金 • 過濾網(wǎng):316L(10μm) • 閥座:PCTFE,PTFE, • 彈簧:316L • 閥芯頂桿:316L CGA580石化高純氣體減壓閥技術(shù)規(guī)范特性參數(shù): • 最大輸入壓力: 0-20MPa • 輸出壓力: 0~0.17, 0~0.35,0~1, 0~1.7,0~3.5MPa可調(diào)(根據(jù)客戶要求) • 安全測(cè)試壓力: 1.5 倍的最大輸入壓力 • 適用溫度: -40℃至+74℃ • 泄漏率:2×10-8 atm cc/sec He • Cv 值:0.08 • 重量1.2kg CGA580高純氣體減壓閥(減壓器)進(jìn)氣螺紋:接高純氣體CGA580等鋼瓶; CGA580高純氣體減壓閥(減壓器)密封可靠、調(diào)壓平穩(wěn),
CGA580石化高純氣體減壓閥技術(shù)規(guī)范氣瓶減壓閥規(guī)格參數(shù): 部位名稱 材質(zhì) ◆母體 316l,brass ◆上蓋 316l,brass ◆膜片 316l ◆過濾網(wǎng) 316l(10μm) ◆閥座 pctfe,ptfe,vespel ◆彈簧 316l ◆閥芯頂桿 316l CGA580石化高純氣體減壓閥技術(shù)規(guī)范壓力特性參數(shù): ◆輸入壓力:15mpa,20mpa,25mpa 6000psi,3000psi,500psi ◆輸出壓力:0-0.1mpa,0-1mpa,0-5mpa,0-10mpa,0-15mpa 0~25,0~100,0~300,0-3000psi ◆規(guī)格:g1/4,g1/2,g5/8,g1 ◆出口規(guī)格:g1/4,g1/2,g5/8,g1,卡套 ◆測(cè)試壓力:1.5倍的*輸入壓力 ◆適用溫度:-40°f 至+165°f(-40℃至+74℃)
CGA580石化高純氣體減壓閥技術(shù)規(guī)范安裝說明: 1、用下扳將減壓器進(jìn)出氣接頭螺紋與氣瓶閥螺紋或高低壓側(cè)管路可靠的連接,一防止氣體泄漏。請(qǐng)勿轉(zhuǎn)動(dòng)減壓器本體,應(yīng)夾持本體,轉(zhuǎn)動(dòng)螺母擰緊。 2、在安裝過程中,應(yīng)確保減壓器進(jìn)、出氣接頭與減壓器連接處不會(huì)發(fā)生松動(dòng),否則將會(huì)導(dǎo)致氣體泄漏,造成安全重大隱患。 3、清除氣瓶和管路系統(tǒng)與減壓器連接位置處的油污、水及灰塵,一旦雜質(zhì)進(jìn)入氣體減壓器內(nèi),將會(huì)導(dǎo)致污染氣體,阻塞氣體通道或產(chǎn)生其他麻煩。 4、如果管路上的螺紋變形,無法與氣體減壓器順利地裝上時(shí),就不要強(qiáng)行連接,否則會(huì)導(dǎo)致管路系統(tǒng)及氣體減壓器上的螺紋損壞,從而引起嚴(yán)重事故。 Installation instructions for pressure reducing valve of imported gas cylinder: 1. Use the pull down to connect the inlet and outlet gas connection thread of the pressure reducer with the screw of cylinder valve or the pipeline at the high and low pressure side reliably, to prevent gas leakage. Do not turn the reducer body. Hold the body and tighten the nut. 2. During installation, it is necessary to ensure that the connection between the inlet and outlet joints of the pressure reducer will not be loose, otherwise, the gas leakage will be caused and the safety and major hidden danger will be caused. 3. Thoroughly remove oil, water and dust at the connection position between cylinder and pipeline system and pressure reducer. Once impurities enter the gas pressure reducer, it will cause pollution of gas, block gas channel or cause other troubles. 4. If the thread on the pipeline is deformed and cannot be installed smoothly with the gas pressure reducer, do not forcibly connect it, otherwise, it will cause the screw damage on the pipeline system and gas pressure reducer, which will cause serious accidents. CGA580石化高純氣體減壓閥技術(shù)規(guī)范
在物理化學(xué)實(shí)驗(yàn)中,經(jīng)常要用到氧氣、氮?dú)?、氫氣、氬氣、二氧化碳等氣體。這些氣體都是貯存在專用的高壓氣體鋼瓶中,使用時(shí)通過氣瓶減壓閥使氣體壓力降至實(shí)驗(yàn)所需范圍,再經(jīng)過其它控制閥門細(xì)調(diào),使氣體輸入使用系統(tǒng)。洛克《DE LOCKE》氣瓶減壓閥就是將氣瓶中的高壓氣體減為實(shí)驗(yàn)及使用工況所需壓力的減壓裝置。
由于氣瓶?jī)?nèi)壓力較高所以需要用減壓器來氣瓶?jī)?nèi)的高壓力氣體降為低壓氣體,保證所需的工作壓力保持穩(wěn)定狀態(tài)。減壓器是將高壓氣體降為低壓氣體、并保持輸出氣體的壓力和流量穩(wěn)定不變的調(diào)節(jié)裝置。 ▼CGA580石化高純氣體減壓閥技術(shù)規(guī)范減壓器的安全使用 (1)氣瓶放氣或開啟減壓器時(shí)動(dòng)作必須緩慢。如果閥門開啟速度過快,減壓器工作部分的氣體因受絕熱壓縮而溫度大大提高,由于放氣過快產(chǎn)生的靜電火花以及減壓器有油污等,也會(huì)引起著火燃燒燒壞減壓器零件。 (2)減壓器安裝前及開啟氣瓶閥時(shí)的注意事項(xiàng):安裝減壓器之前,要略打開氣瓶閥門,吹除污物,以防灰塵和水分帶入減壓器。在開啟氣瓶閥時(shí),瓶閥出氣口不得對(duì)準(zhǔn)操作者或他人,以防高壓氣體突然沖出傷人。 (3)在工作過程中必須注意觀察工作壓力表的壓力數(shù)值。停止工作時(shí)應(yīng)先松開減壓器的調(diào)壓螺釘,再關(guān)閉氣瓶閥,并把減壓器內(nèi)的氣體慢慢放盡,這樣可以保護(hù)彈簧和減壓活門免受損壞。工作結(jié)束后,應(yīng)從氣瓶上取下減壓器加以妥善保存。 (4)減壓器必須定期校修,壓力表必須定期檢驗(yàn),這樣做是為了確保調(diào)壓的可靠性和壓力表讀數(shù)的準(zhǔn)確性。在使用中如發(fā)現(xiàn)減壓器有漏氣現(xiàn)象、壓力表針動(dòng)作不靈等,應(yīng)及時(shí)維修。 (5)減壓器凍結(jié)的處理。減壓器在使用過程中如發(fā)現(xiàn)凍結(jié),用熱水或蒸汽解凍,絕不能用火焰或紅鐵烘烤。減壓器加熱后,必須吹掉其中殘留的水分。 (6)減壓器必須保持清潔。減壓器上不得沾染油脂、污物,如有油脂,必須在擦拭干凈后才能使用。 (7)各種氣體的減壓器及壓力表不得調(diào)換使用。 |